FASTBLAZER 8840 VERSION 2.14 RELEASE NOTES WHAT'S IN THIS RELEASE NOTE? Version 2.14 incorporates V.34b functionality (33.6Kbps) in the FastBlazer 8840 and FastBlazer 8840R. Read this document carefully before placing the modem in service. NOTE: Unless otherwise indicated, the term FastBlazer 8840 indicates the standalone (8840) and rackmount (8840R) versions of the product. The organization of this Release Note is as follows: - FastBlazer 8840 Overview - Enhancement Information - Operational Guidelines - Documentation Corrections - Technical Support The information in this Release Note supports the following documentation: FastBlazer 8840 Technical Reference Manual EM-8840AE-001 FastBlazer 8840 User's Guide EM-8840UE-001 FastBlazer 8840 Quick Reference Card EB-000402-002 FASTBLAZER 8840 OVERVIEW The FastBlazer 8840 has 2 methods for entering information: front panel keypad with LCD, and "AT" command entry. The front panel keypad with LCD uses a Root, Branch, and Leaf Node structure to access the different menu levels. The arrow keys are one way to move through the various menu levels. Another way is through the use of a "Hot Key". A Hot Key is a four-digit shortcut that moves you to different levels in the LCD. A HotKey is executed using the "F" key, a four-digit number and the enter key. The Quick Reference Card provides a visual guide to front panel navigation. "AT" commands are entered using an asynchronous terminal connected to either the NMS port or the DTE port. AT command entry has the advantage of allowing you to enter numerous settings at one time. For a full discussion of AT command entry, refer to Chapter 5 of the Technical Reference Manual or Section 5 of the User's Guide. The FastBlazer 8840 has 30 configuration storage locations. The first 5 (0-4) are user- defined and the remaining 25 (5-29) are factory-defined. All 30 configurations are loaded using the ATZn (where n is a value from 0 -29) command. The factory-defined configurations cover leased line and PSTN operations, asynchronous and synchronous modes, dial restoral, V.25bis, and many other common configurations. The default standard for each factory-defined configuration is V.34b (%S0). ENHANCEMENT INFORMATION NOTE: For your convenience, relevant Version 2.12 and Version 2.124 information is provided in this Release Note. VERSION 2.14 The addition of V.34b affects the AT command operation of the FastBlazer 8840 as follows: %S Command- %S0= V.34b auto %S23= V.34b auto NTC %S24= V.34 auto %S25= V.34b only *M Command- *M17= Maximum connect rate of 31.2Kbps *M18= Minimum connect rate of 33.6Kbps *W Command- *W17= Minimum connect rate of 31.2Kbps *W18= Minimum connect rate of 33.6Kbps Result Codes- Digit 53= CONNECT 31200 Digit 54= CONNECT 33600 The addition of V.34b affects the display characteristics and operation of the LCD front panel. LCD: AT Command: AT%S Default= V.34b Auto Standard Bits per Second V.34b Auto.33.6Kbps to 300bps in any mode V.34b Only.33.6Kbps to 2400bps in V.34bonly V.34b Auto NTC * 33.6Kbps to 300bps in any mode except V.32terbo V.34 Auto 28.8Kbps to 300bps in any mode V.34 Only 28.8Kbps to 2400bps in V.34 only V.32terbo Auto.19.2Kbps to 300bps in any mode V.32terbo Only 19.2Kbps to 4800bps in V.32terbo only V.32bis Auto.14.4Kbps to 300bps in any mode V.32bis Only 14.4Kbps to 4800bps in V.32bis only V.32 Only 9600bps or 4800bps in V.32 only V.22bis Only 2400bps or 1200bps in V.22bis only V.22 Only 1200bps V.21 Only 300 bps Bell 212 Only.1200bps Bell 103 Only.300bps V.23 Only 1200bps and 75bps * V.34b Auto NTC means the V.32terbo handshake is not presented during the call negotiation. This provides compatibility with devices that do not support V.32 terbo operation. Use the Enter key to save the entry. NOTES: 1 When you select a standard, the modem automatically sets Max Rate and Min Rate values to the rates specified by the standard. 2. Do not set a max rate lower than 4800bps when using V.34b auto. 3. The V.34b and V.34 rate depends on local regulatory policy and/or the negotiated speed during the handshake sequence. VERSION 2.124 (COUNTRY CONFIGURATION 202 ONLY) To implement the 28.8Kbps asynchronous feature in the FastBlazer 8840R modem, enter the command ATS61=15. NOTES: 1. When this command is enabled, all AT commands are disabled until you exit this mode. 2. This feature applies in answer mode only. To exit the 28.8Kbps asynchronous feature, remove the modem card from the chassis, and then while holding in the Data button, place the modem card back in the chassis. This allows you to use the full complement of AT commands. VERSION 2.12 General receiver performance is improved (e.g., echo cancellation). Improved speed shift negotiation provides consistent higher throughput results. In error correcting modes, the addition of variable (flexible) length buffers improves overall throughput. In error correcting modes, improvements in round-trip delay allow faster recovery from a failed data packet in error correcting modes. The recovery speed due to a broken frame is improved. The method for handling a DC1 during an ODP is enhanced to handle certain non-V.42 standard modems. The LAP-M Buffer Length option (implemented using S-Register 77) is modified to operate as follows: S77 Setting Window Size Maximum Buffer Length 0 16 128 1 64 64 2 32 128 3 21 192 4 (default) 16 256 OPERATIONAL INFORMATION Managing Your FastBlazer 8840R Modem: 1) Use ViewBlazer NMS software Version 1.14 and higher to manage your FastBlazer 8840R modem .2) Use AP2825R (or AP2825E) Network Controller software Version 1.24 and higher to manage your FastBlazer 8840R modem. If you need to inquire about the current version for any of your Telebit software, contact your point-of-sale representative for more information. The FastBlazer 8840 does not go off-hook when ring voltage is high. Do not set a Max Rate (*M) lower than 4800bps when using V.34b autobaud (%S0). &R1 must be part of any configuration that uses the &M, *V2, or *V3 command. If V.13 is enabled (%A1), set &C (DCD Control) to value of 1, 2, or 3, and &R (RTS/CTS Options) to a value of 1. If you perform a Local Analog Loopback with self-test (LAL-ST) with error correction (&E) enabled (i.e., &E is greater than zero), the error count is not displayed on the DTE screen at the end of the test. The number displayed in the "Retrains:" field of the front panel LCD (HotKey 0007) indicates the total number of retrains and/or speed shifts during the current call. This number may be larger than the setting of S74 due to the number of speed shifts that may have occurred. It is recommended that you not perform a Leased Line Remote Configuration from a FastBlazer 8840 rackmount modem in the local chassis to a remote FastBlazer 8820 standalone modem. DOCUMENTATION CORRECTIONS Register S61 in Appendix F now includes the DTE rates 57600bps, 76800bps, and 115200bps. Register S30 and Register S60 information in Appendix F is corrected as follows: S30 Bit 4 Bit 3 PARITY 0 0 (= 0) Disable parity 0 1 (= 1) Odd parity 1 0 (= 2) Enable parity 1 1 (= 3) Even parity S60 Bit 1 Bit 0 PARITY 0 0 (= 0) Disable parity 0 1 (= 1) Odd parity 1 0 (= 2) Enable parity 1 1 (= 3) Even parity The AT1 command returns a checksum value (instead of an OK message). The K dial modifier (ATDnK) switches a connection from synchronous mode to asynchronous mode. This modifier was previously omitted from the documentation. In the User's Guide and Technical Reference Manual, the Result Code CONNECT 75 (with a digit code of 99) is added. It was previously omitted from the documentation. TECHNICAL SUPPORT Telebit Corporation (Headquarters) One Executive Drive Chelmsford, MA 01824 Technical Support Hours: 8 A.M. to 8 P.M. (Eastern Time) Telephone: 508.656.9453 Facsimile: 508.656.9445 Telebit Europe Limited (Europe) Lockside Place, Mill Lane Newbury, Berkshire United Kingdom RG14 5QS Technical Support Hours: 9 A.M. to 5 P.M. (Greenwich Time) Telephone: 44.635.528730 Facsimile: 44.635.528311 Telebit Corporation (Hong Kong) Room 4402-3, Hopewell Center 183 Queen's Road East Wanchai Hong Kong Telephone: 852.2847.3377 Facsimile: 852.2868.1909 Other Communications Channels E-Mail: modems@telebit.com (modem support) support@telebit.com (network products support) NOTE: For urgent requests, please follow-up your E-Mail message with a telephone call to the 1.508.656.9453 support number. BBS: WorldBlazer 508.656.9456 FastBlazer 508.656.9457 FTP: ftp.telebit.com Name anonymous Password "email address" or "guest" download files /pub/tech-support upload files /pub/tmp CompuServe: GO TELEBIT World Wide Web (WWW) http://www.telebit.com Document Part Number: EB-000229-001