FastBlazer 8840 Version 2.12 Release Notes Overview Version 2.12 of the FastBlazer 8840 integrates various enhancements, configuration changes, and documentation corrections since the release of Version 2.1 in April 1995. The organization of this Release Note is as follows: Basic Operation Enhancements Country Configuration Changes Documentation Corrections Operational Information Technical Support The information in this Release Note supports the following documentation: FastBlazer 8840 Technical Reference Manual EM-8840AD-001 FastBlazer 8840 Technical Reference Manual (UK) EM-8840AD-400 FastBlazer 8840 User's Guide EM-8840UD-001 FastBlazer 8840 User's Guide (UK) EM-8840UD-400 FastBlazer 8840 Quick Reference Card EB-000402-001 FastBlazer 8840 Software Download Guide EB-000401-001 WARNING: The file names for the 8840 and 8820 flash code are IDENTICAL! We strongly recommend you place these files in separate directories. For example: FLSH 8840 and FLSH 8820. If you mistakenly download the wrong flash file to a device, that device will not work, and you will have to return it to a Telebit Repair Facility. Please call Telebit Technical Support if you have any questions. Basic Operation The FastBlazer 8840 has 2 methods for entering information: front panel keypad with LCD, and "AT" command entry. The front panel keypad with LCD uses a Root, Branch, and Leaf Node structure to access the different menu levels. The arrow keys are one way to move through the various menu levels. Another way is through the use of a "Hot Key". A Hot Key is a four-digit shortcut that moves you to different levels in the LCD. A HotKey is executed using the "F" key, a four-digit number and the enter key. The Quick Reference Card provides a visual guide to front panel navigation. "AT" commands are entered using an asynchronous terminal connected to either the NMS port or the DTE port. AT command entry has the advantage of allowing you to enter numerous settings at one time. For a full discussion of AT command entry, refer to Chapter 5 of the Technical Reference Manual or Section 5 of the User's Guide. The FastBlazer 8840 has 30 configuration storage locations. The first 5 (0-4) are user-defined and the remaining 25 (5-29) are factory-defined. All 30 configurations are loaded using the ATZn (where n is a value from 0 -29) command. The factory-defined configurations cover leased line and PSTN operations, asynchronous and synchronous modes, dial restoral, V.25bis, and many other common configurations. The default standard for each factory-defined configuration is V.34 (%S0). ENHANCEMENTS - General receiver performance is improved (e.g., echo cancellation). - Improved speed shift negotiation provides consistently higher throughput results. - In error correcting modes, the addition of variable (flexible) length buffers improves overall throughput. - In error correcting modes, improvements in round-trip delay allow faster recovery from a failed data packet. - In error correcting modes, the recovery speed due to a broken frame is improved. - The method for handling a DC1 during an ODP is enhanced to handle certain non-V.42 standard modems. - The LAP-M Buffer Length option (implemented using S- Register 77) is modified to operate as follows: S77 Setting Window Size Maximum Buffer Length 0 16 128 1 64 64 2 32 12 3 21 192 4 (default) 16 256 Country Configuration Changes The following changes apply to Holland (country configuration 0205): - a value of one for S0 (Ring to Answer On) is valid. - the blacklisting requirement is removed. The following changes apply to France (country configuration 0209): - default value for S0 is changed to 3 - valid values for S0 are 0 and 3 (1 and 2 are not valid values). - default value for S6 is changed to 10 (that is the only valid value). - modem waits until ring voltage is absent before going off-hook. - pulse dialing is not allowed. - %T command is automatically set depending on line type: %T0=PSTN; %T1=2-wire leased line; %T3=4-wire leased line. - the 4-wire leased line transmit level is fixed at -15dBm. - the 2-wire leased line transmit level is fixed at -12dBm. The following changes apply to Sweden (country configuration 0210): - pulse dialing is not allowed. blind dialing is allowed. The following changes apply to Norway (country configuration 0211): - pulse dialing is not allowed. dialtone detection after dialing is implemented; if a secondary dialtone is detected within 15 seconds of dialing, the call is aborted. the W modifier is no longer valid. The maximum value for S6 is 9 in Denmark (country configuration 0212). The valid range for S6 is 2-4 in Finland (country configuration 0237). The valid range for S68 is 0-255 in Poland(country configuration 0253). The following changes apply to New Zealand (country configuration 0403): - a blacklisting requirement that allows a maximum of - 5 calls in a 60 minute period is added. - the auto-redial timer is set to 60 seconds. The following changes apply to Japan (country configuration 0500): - a blacklisting requirement that allows a maximum of - 3 calls in a 3 minute period is added. - the maximum value for S7 is 57. - the maximum value for S36 is 15. - the default value for &G is 0. - the default value for S6 is 3. Documentation Corrections - In the Technical Reference Manual, Note 1 for the &M (Asynchronous/Synchronous Mode Selection) command is corrected as follows: 1. &R1 must be part of any &M1, &M2, or &M3 setting. - In the LCD description portion of the User's Guide and Technical Reference Manual, the following statement is added to the Sync/Dial Async, Sync/Dial DTR, Sync/Dial Man menu options in the Async/Sync menu (HotKey 0601): "The Off/® RTS Data option under the CTS Control menu (HotKey 0707) must be included in any configuration using this option." - In the LCD description portion of the User's Guide and Technical Reference Manual for the DTR Option menu (HotKey 0701), the reference "for use in asynchronous mode only" was omitted from the introductory sentence. Additionally in the User's Guide, this same reference was omitted in Table 8 for the &D (DTR Control) command. - The ATI1 command returns a product checksum value (instead of an OK message). - The K modifier (ATDTK) switches a connection from synchronous mode to asynchronous mode. This modifier was previously omitted from the documentation. - In the User's Guide and Technical Reference Manual, the result code CONNECT 75 (with a digit code of 99) is added. It was previously omitted from the documentation. - In the User's Guide and Technical Reference Manual for the Bit Mapped S-Register Summary appendix, the correct information for S30 Bits 4 and 3, and S60 Bits 1 and 0 is: S30 Bit 4 Bit 3 PARITY 0= Disable parity 1= Odd parity 2= Disable parity 3= Even parity S60 Bit 1 Bit 0 DTE PARITY 0= Disable parity 1= Odd parity 2= Disable parity 3= Even parity Operational Information - ViewBlazer software Version 1.0 will not manage FastBlazer 8840 modems with V.34 functionality (Version 2.0 and higher). Use ViewBlazer software Version 1.01 and higher to manage FastBlazer V.34 modems. If you need to inquire about the current version of FastBlazer software, contact your point-of-sale representative for more information. - WARNING: The file names for the 8840 and 8820 flash code are IDENTICAL! We strongly recommend you place these files in separate directories. For example: FLSH 8840 and FLSH 8820. If you mistakenly download the wrong flash file to a device, that device will not work, and you will have to return it to a Telebit Repair Facility. Please call Telebit Technical Support if you have any questions. - The FastBlazer 8840 does not go off-hook when ring voltage is high. - Available speeds in V.34 are based on either local regulatory policy and/or the actual connection speed established during the handshake sequence. The available ranges are 28.8Kbps to 2400bps. - Do not set a Max Rate (*M) lower than 4800bps when using V.34 autobaud (%S0). - &R1 must be part of any configuration that uses the &M, *V2, or *V3 command. - If V.13 is enabled (%A1), set &C (DCD Control) to value of 1, 2, or 3, and &R (RTS/CTS Options) to a value of 1. - If a FastBlazer 8840 has &E5 or &E 6 as part of the configuration AND is connected with another Telebit modem other than a FastBlazer 8840 (e.g., WorldBlazer, T3000), set S183 in that Telebit modem to a value greater than 30 (100 is recommended). - If you perform a Local Analog Loopback with self-test (LAL-ST) with error correction (&E) enabled (i.e., &E is greater than zero), the error count is not displayed on the DTE screen at the end of the test. - The number displayed in the "Retrains:" field of the front panel LCD (HotKey 0007) indicates the total number of retrains and/or speed shifts during the current call. This number may be larger than the setting of S74 due to the number of speed shifts that may have occurred. Technical Support Product Support Locations Telebit Corporation (Headquarters) (Massachusetts) One Executive Drive Chelmsford, MA 01824 Technical Support Hours: 8 A.M. to 8 P.M. Eastern Time (ET) Telephone: 508.656.9453 Facsimile: 508.656.9445 Telebit Corporation (Europe/Middle East/Africa) Lockside Place, Mill Lane Newbury, Berkshire United Kingdom RG145QS Technical Support Hours: 9 A.M. to 5 P.M. Greenwich Time (GT) Telephone: 44.635.528730 Facsimile: 44.635.528311 Telebit Corporation (Hong Kong) Room 4402-3, Hopewell Center 183 Queen's Road East Wanchai Hong Kong Telephone: 852.2847.3377 Facsimile: 852.2868.1909 Other Communication Channels Internet E-Mail: support@telebit.com NOTE: For urgent requests, please follow-up your E-Mail message with a telephone call to the 1.508.656.9453 support number. FTP: ftp.telebit.com Name anonymous Password "email address" or "guest" download files /pub/tech-support upload files /pub/tmp CompuServe: GO TELEBIT AppleLink: Telebit World Wide Web (WWW) http://www.telebit.com