Manufacturer/Support Developer's Name: Cott Lang Thunderbolt Technologies (619) 251-0609 - Alternate Reality BBS 1:219/801 802 - FidoNet 50:50/0 100/1 - RGSNet Renegade v05-31-94 for DOS: DIP Switches: 3, 5, and 8 DOWN(ON) The 05-09-94 version, along with this version, both require that the modem be completely setup from scratch. Run RENEGADE.EXE. When the Wait for Caller screen comes up, type "S" for System Config, then "B" for Modem/Node Configuration. Configure as shown below: +----------------------- Modem Responses ------------------+ Init OK Busy OK Ring RING Secure ARQ 300 CONNECT| 1200 CONNECT 1200 2400 CONNECT 2400 4800 CONNECT 4800 7200 CONNECT 7200 9600 CONNECT 9600 12000 CONNECT 12000 14400 CONNECT 14400 16800 CONNECT 16800 19200 CONNECT 19200 38400 CONNECT 38400 FAX CONNECT FAX +----------------------------- ---------------------------------- + Now type "R" to bring up the modem result codes. Make sure the screen is set up as show below: Modem configuration Result Codes - A. NO CARRIER NO CARRIER B. RELIABLE /ARQ C. OK OK D. RING RING E. CALLER ID F. ID in user Off note G. CONNECT 300 CONNECT 300 H. CONNECT 600 I. CONNECT 1200 CONNECT 1200 J. CONNECT 2400 CONNECT 2400 K. CONNECT 4800 CONNECT 4800 L. CONNECT 7200 CONNECT 7200 M. CONNECT 9600 CONNECT 9600 N. CONNECT 12000 CONNECT 12000 O. CONNECT 14400 CONNECT 14400 P. CONNECT 16800 CONNECT 16800 Q. CONNECT 19200 CONNECT 19200 R. CONNECT 21600 CONNECT 21600 S. CONNECT 24000 CONNECT 24000 T. CONNECT 26600 CONNECT 26400 U. CONNECT 28800 CONNECT 28800 V. CONNECT 38400 W. CONNECT 57600 X. CONNECT 115200 As you can see in the above table, the result message "CONNECT 26600", should read "CONNECT 26400". Note: Renegade requires that a FOSSIL driver be loaded before the BBS system is run. The port speed specified in the FOSSIL driver must remain consistent throughout the BBS. For example, if you have the port speed in the FOSSIL driver set to 38400, you must specify 38400 in Renegade and the locked rate should specify 38400. All door programs must also be set to 38400(though most now read directly from the FOSSIL driver). _______________________________________________________________________ Renegade v1-2-94 and earlier for DOS: DIP Switches: 3, 5, and 8 DOWN(ON) Run RENEGADE.EXE. When the Wait for Caller screen comes up, hit "S" for System Configuration then "B" for Modem/Node Configuration. Set you software as shown below: Modem/Node Configuration 1 Maximum baud rate 38400 2 COM port number 2 3 Modem init string AT&FV&B1&H1&R2&A0&K3X4H| 4 Modem answer string ATA| 5 Modem hangup string ATH0| 6 Modem offhook string ATH1| 7 Inactivity init time 30 8 COM port locking On 9 Locked baud rate 38400 baud 0 Digiboard support Off A CTS/RTS flow control On B XON/XOFF flow control Off C ACS for this node D Path for door files E TeleConf Normal [Rgsysop] F TeleConf Anon [??] G TeleConf Global [Rgsysop GLOBAL] H TeleConf Private [Rgsysop PRIVATE] I Com port IRQ string J Com port address str R Modem result codes (Pull down menu shown below) C, D, I and J are all optional. They are configured by the Sysop and are not required. Next click "R" to configure the modem result codes and set as shown below: Modem configuration - Result Codes Normal Alternate A. No carrier 3 B. CONNECT 300 1 0 C. CONNECT 1200 5 0 D. CONNECT 2400 10 0 E. CONNECT 4800 18 0 F. CONNECT 7200 20 0 G. CONNECT 9600 13 0 H. CONNECT 12000 21 0 I. CONNECT 14400 25 0 J. CONNECT 16800 47 0 K. CONNECT 19200 85 0 L. CONNECT 21600 91 0 M. CONNECT 24000 99 0 N. CONNECT 26600 103 0 O. CONNECT 28800 107 0 In versions 12-25-93 and 1-2-94, you can not change options M, N, or O on the result code screen. Note: Renegade requires that a FOSSIL driver be loaded before the BBS system is run. The port speed specified in the FOSSIL driver must remain consistent throughout the BBS. For example, if you have the port speed in the FOSSIL driver set to 38400, you must specify 38400 in Renegade and the locked rate should specify 38400. All door programs must also be set to 38400(though most now read directly from the FOSSIL driver).