![Digi logo](https://www.digi.com/digi/media/nav/logo-digi.png "Digi International Inc.")  
**DIGI INTERNATIONAL**  
9350 Excelsior Blvd, Suite 700  
Hopkins, MN 55343, USA  
+1 (952) 912-3444 | +1 (877) 912-3444  
[www.digi.com](https://www.digi.com)

Digi XBee Industrial Gateway Cellular Release Notes
===================================================
## Digi XBee Industrial Gateway Cellular
## Version 3.2.31.20 (July 2022)

---

INTRODUCTION
------------
These are the release notes for Digi XBee Industrial Gateway Cellular.

The XBee Gateway is a small ZigBee to IP gateway that provides low-cost
IP networking of RF devices and sensor networks. Featuring an easy
development environment, XBee Gateway enables custom applications to run
locally while interfacing across existing Ethernet/Wi-Fi networks for WAN
connectivity to cloud-based software applications.

The XBee Gateway products feature an end-to-end development environment
based on Digi's DIA framework, allowing for rapid M2M-specific
application development on the industry standard Python scripting engine.
Digi ESP provides an IDE featuring device detection, debugging, compiling
and downloading of Digi DIA/Python code to Digi gateways.

Digi Remote Manager, a Digi-hosted remote management service, offers a
platform for secure, scalable access to an unlimited number of remote
assets. In addition, the Remote Manager web services provide seamless
integration from Digi gateways into customer back office applications.

SUPPORTED PRODUCTS
------------------

  * XBee Industrial Gateway - ZB to HSPA+ GSM
  * XBee Industrial Gateway - ZB Pro to LTE Cat 1

KNOWN ISSUES
------------

* OTA update of sleepy XBee 3 nodes with long sleep periods
  (greater than several seconds) may not succeed.
  Workaround: configure the node with a shorter sleep period
  or disable sleep while updating.

UPDATE CONSIDERATIONS
---------------------

  * As of firmware version 3.2.30.4, the factory default settings for ADDP
    and HTTP/HTTPS web UI access have changed. Updating to 3.2.30.4 does not
    change the existing configuration of the gateway.

    * ADDP is now Read-Only by default.
    * Accessing the web interface by HTTP is disabled by default; access to the
      web interface by HTTP (port 80) redirects to HTTPS (port 443).
    * Accessing the configuration of the product via the web interface now requires
      user authentication. Use the `python` username and password to authenticate.

  * XBee Gateway devices shipped with firmware version 3.2.30 or higher are
    manufactured with a unique per-device password. Devices shipped with older
    firmware have no unique per-device password.

  * Be aware that firmware downgrade is not supported on XBee Gateway devices.

UPDATE BEST PRACTICES
---------------------
Digi recommends the following best practices:

1. Test the new release in a controlled environment with your application before
   you update production devices.
2. Unless otherwise noted, apply updates in the following order:
    1. Device firmware
    2. Modem firmware
    3. XBee firmware
    4. Configuration
    5. Application

Digi recommends Digi Remote Manager for automated device updates. For
more information, go to
[https://www.digi.com/products/iot-platform/digi-remote-manager](https://www.digi.com/products/iot-platform/digi-remote-manager).

If you prefer manually updating one device at a time, follow the instructions
in the XBee Gateway user guide: [Update firmware from the XBee Gateway web interface][ug-update]

[ug-update]: https://www.digi.com/resources/documentation/Digidocs/90001542/Default.htm#tasks/t-update-firmware-from-web-interface.htm

TECHNICAL SUPPORT
-----------------

Get the help you need via our Technical Support team and online
resources. Digi offers multiple support levels and professional
services to meet your needs. All Digi customers have access to product
documentation, firmware, drivers, knowledge base and peer-to-peer
support forums.

Visit us at [https://www.digi.com/support](https://www.digi.com/support) to find
out more.

---

CHANGE LOG
----------

## VERSION 3.2.31.20 (July 2022)
This is a recommended release.

### ENHANCEMENTS

  * XBee Over-the-Air (OTA) can now update XBee RR and S2C NG Zigbee firmware.


### BUG FIXES

  * Reliability improvements to XBee 3 and XBee RR Over-the-Air
    (OTA) updates. [XBGW-3187]
  * Reliability improvements to XBee S2/S2C Over-the-Air
    (OTA) updates. [XBGW-3225]
  * Each XBee unicast transmission is now preceded by a Create Source Route
    API frame, to improve data reliability. [XBGW-3199]
  * On a failed XBee OTA update, attempt to update with other XBee nodes
    on the network first, before trying Recovery Mode. [XBGW-3236]
  * Adjust implicit timeout for Remote AT Commands to improve reliability
    on large XBee networks. [XBGW-3184]


## VERSION 3.2.31.12 (September, 2021)
This is a recommended release.

### ENHANCEMENTS

  * Improved timeout behavior of XBee 3 Over-the-Air (OTA) updates.
  * Updated ppp and busybox packages to receive security issue fixes
      - ppp
          - CVE-2018-11574
          - CVE-2020-8597
          - CVE-2014-3158
      - busybox
          - CVE-2018-1000517
          - CVE-2018-1000500
          - CVE-2016-6301
          - CVE-2016-2148
          - CVE-2018-20679
          - CVE-2019-5747
          - CVE-2013-1813
      NOTE: The busybox change includes fixes that modify shell script
      and command behavior. As with every new release it is strongly
      recommended that thorough validation testing be performed in a
      test environment with the new version prior to deployment into a
      production environment.
  * Modify cellular configuration in preparation for the global 3G
    sunset.

### BUG FIXES

  * Fix repeated "size error" message in xbee.log. [XBGW-3092]
  * XBee OTA updates could get stuck in the "Scheduled" state. [XBGW-3093]
  * XBee OTA updates could cause the xbee daemon to restart, losing
    memory of network state and update progress. [XBGW-3170]


## VERSION 3.2.30.9 (September 2020)
This is a recommended release

### ENHANCEMENTS

  * XBee Over-the-Air (OTA) can now update XBee 3 device firmware
    and file system images.


## VERSION 3.2.30.6 (May 2020)
This is a recommended release.

### SECURITY FIXES

  * High level security updates
    (CVSSv3 scoring 7.3 - CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N)
    to address common weakness enumerations (CWE-250) -
    Execution with unnecessary privilege within the product.
    These were discovered and reported to Digi by Jake Valletta and Sam Sabetan
    from FireEye Mandiant. [XBGW-3005]

  * Updated to OpenSSL 1.0.2u


## VERSION 3.2.30.4 (December 2019)
This is a recommended release.

### NEW FEATURES

  * Changes for California SB-327. See ENHANCEMENTS below.

  * Created new Authentication web page.
    * New web page added allowing the python user password to be changed.
      [XBGW-2965]
    * Web UI authentication enable/disable option added to web UI. [XBGW-2966]

  * RCI `do_command` `set_password` can be used to set the python
    user password.  See product documentation for more information. [XBGW-2967]


### ENHANCEMENTS

  * Changes for California SB-327

    In order to comply with regulations in the state of California
    (SB-327), this firmware now supports being manufactured with a
    unique per-device password.  Existing products manufactured prior
    to this change will continue to default to the prior fixed password
    'dbps' for the python user, but will be impacted by changes to defaults
    that have been made.

    When applicable, this password is the initial factory default value
    for the 'python' user and can be found printed on a label attached
    to the product.  As always, Digi recommends that users take the
    opportunity to change the password to a value known only to themselves
    when performing the initial configuration of the product.

    * The default factory setting for ADDP is now Read-Only.
      This means the XBee Gateway can be discovered using the
      Digi Device Discovery tool, but configuration may only be performed
      via the web interface, SSH, or through Digi Remote Manager.
      Note that ADDP on XBee Gateway does not support a password -
      keep this in mind if you choose to configure ADDP to be Read-Write,
      or if upgrading an existing product where ADDP is Read-Write by default.

    * Accessing the configuration of the product via the web interface
      now requires user authentication.  You may use the `python` username
      and password to authenticate.

    * Accessing the web interface by HTTP is now disabled in factory defaults;
      access to the web interface by HTTP (port 80) redirects to HTTPS
      (port 443).

  * This firmware has been tested and confirmed to operate with the
    new 20.00.016 and 20.00.526 firmware for the Telit LE910 modem
    module.

### SECURITY FIXES

  * Fixes to address Selective ACK security issues
    * CVE-2019-11477 SACK Panic
    * CVE-2019-11478 SACK Slowness
    * CVE-2019-11479 Excess Resource Consumption Due to Low MSS Values


### BUG FIXES

None.


## VERSION 3.2.29.7 (February 11, 2019)
This is a recommended release.

### NEW FEATURES

None.

### ENHANCEMENTS

None.

### SECURITY FIXES

None.

### BUG FIXES

  * When resetting the XBee Gateway to factory defaults, the factory default
    password will now be used (user/pass: `python`/`dbps`). [XBGW-2781]
  * Fixed issue where DNS lookups were being cached even if the zone/file CNAME
    mapping had been updated. [XBGW-2904]


## VERSION 3.2.27.13 (February 6, 2019)
This is a recommended release.

### NEW FEATURES

  * This release extends capability in cell module management to assist
    upgrading modules impacted by an Intel chipset defect. This defect
    affects certain modules on the Verizon network after March 30, 2019.
    More information may be found at
    [https://www.digi.com/verizon-upgrade](https://www.digi.com/verizon-upgrade).

    Currently the issue is known to include certain revisions of the
    Telit LE910 used on some XBee Industrial Gateway variants supported by
    this firmware.

### ENHANCEMENTS

None.

### SECURITY FIXES

None.

### BUG FIXES

None.


Release Notes Part Number: 93001304