How do you emulate standard COM ports with the ISA Classic board? How do you emulate standard COM ports with the ISA Classic board? Run the Classic CFG utility from a clean DOS boot
Select F3 to Edit New Profile
Select "No" for PnP Mode
Select "Digi" for Control Register Int Mode
Select a unique value for the Control Register I/O
Select IRQ 3 for the Control Register IRQ
Select 3F8 for the port address for Port 1, 2F8 for the port address for Port 2, and unique I/O addresses for all other ports listed
Tab over to the IRQ field located next to the I/O Base setting for Port 1
Use the arrow keys to select IRQ 4
Select F5 to Write New Profile to Board
Select F6 to Write New Profile to Disk
Select and name the profile you created
Select F10 to Exit