My EPC/CON or C/CON concentrator hangs at P2 and does not finish booting to AC. My EPC/CON or C/CON concentrator hangs at P2 and does not finish booting to AC.
Symptom: My EPC/CON or C/CON concentrator hangs at P2 and does not finish booting to AC.
Cause:
- Timing is set incorrectly on either the host adapter, the concentrator, (or the modem ((csu/dsu)) if a remote concentrator).
- The cable or the phone line is faulty.
- The last concentrator on the chain is not terminated.
- The host adapter is malfunctioning.
Solutions:
Make sure the timing settings match on the host adapter, the concentrator, and the modem (csu/dsu).
Verify that the cables and/or the phone lines are good.
Terminate the last concentrator on the chain.
Run the appropriate diagnostics to verify the host adapter.
Related Information:
http://ftp.digi.com/support/utilities/diags/
|