MPI Port Configuration Utility core dumps, shows error 50, or quits abnormally. MPI Port Configuration Utility core dumps, shows error 50, or quits abnormally. PCU requires that lp and uucp services are installed on the system.
- If you do not have lp and uucp installed, then PCU will not
function.
- If you have these services installed and you get a PCU error,
cd /etc/digi/epca (or pcxx)
and remove the .conf and .prnt files for the affected device (XEM11A
or CX11A are examples of device references).
- If you are running a version earlier than SCO 5.0.4 then you may
also need to:
Check to make sure that there is a symbolic link between
/etc/inittab --> /var/opt/K/SCO/Unix/5.**/etc/inittab
if the symbolic link is gone, run
custom-->software-->verify system-->
broken missing symbolic links-->fix discrepancies
|