www.digi.com
  Advanced Search
Product Selector
     
  Technical Support
Drivers

Firmware Upgrades

FAQs

Product Documentation

Cabling

Support Tools

Legacy Products

About Digi Support

Knowledge Base

Online Support Request

FTP Site



Related Links
Inside Out Networks


 
Solutions Partners Support and Training Corporate Info Where to Buy Order Where to Buy Site Map Contact Us
Home > Support >kbase >
PortServer II Frame Relay/WAN Trace Examples
PortServer II Frame Relay/WAN Trace Examples PortServer II Frame Relay/WAN Trace Examples

App Note: Portserver II Frame Relay Trace Samples

Typing the following command will give live frame relay communication tracing:

#>  set trace state=on mode=concurrent mask=frame:debug

The following command will turn off the tracing(this can be typed while trace 
data is scrolling):

#>  set trace state=off

Successful Frame Link Response

This is a sample of a successful frame relay communication link: 11:30:13 Frame DEBG: Port 16 received frame 11:30:13 Frame INFO: LCB on port 16 received LMI frame 11:30:13 Frame DEBG: received Report Type IE 11:30:13 Frame DEBG: Link Integrity message 11:30:13 Frame DEBG: received Link Integrity IE 11:30:23 Frame INFO: LMI on port 16 waiting for Link Integrity Status Response 11:30:23 Frame DEBG: Port 16 received frame 11:30:23 Frame INFO: LCB on port 16 received LMI frame

Wrong LMI Response

The LMI setting is assigned by your service provider. This is a sample of an incorrect LMI setting: 11:34:33 Frame WARN: LMI on port 16 fault event: status response not received 11:34:33 Frame CRIT: LMI on port 16 in error: data traffic stopped 11:34:33 Frame DEBG: N393 = 0 N392 = 0 11:34:33 Frame INFO: LMI on port 16 waiting for Full Status Response 11:34:43 Frame WARN: LMI on port 16 fault event: status response not received 11:34:43 Frame DEBG: N393 = 1 N392 = 1 11:34:43 Frame INFO: LMI on port 16 waiting for Full Status Response 11:34:53 Frame WARN: LMI on port 16 fault event: status response not received 11:34:53 Frame DEBG: N393 = 2 N392 = 2

Wrong DLCI Response

The DLCI setting is assigned by your service provider. This is a sample of an incorrect DLCI setting: 11:45:23 WAN CRIT: framein:ioctl failed 11:45:24 Frame WARN: new frame relay open 11:45:24 WAN CRIT: framein:ioctl failed 11:45:25 Frame WARN: new frame relay open 11:45:25 WAN CRIT: framein:ioctl failed 11:45:26 Frame WARN: new frame relay open 11:45:26 WAN CRIT: framein:ioctl failed 11:45:27 Frame WARN: new frame relay open 11:45:27 WAN CRIT: framein:ioctl failed 11:45:28 Frame WARN: new frame relay open 11:45:28 WAN CRIT: framein:ioctl failed 11:45:29 Frame WARN: new frame relay open 11:45:29 WAN CRIT: framein:ioctl failed 11:45:29 Frame INFO: LMI on port 16 waiting for Link Integrity Status Response 11:45:29 Frame DEBG: Port 16 received frame 11:45:29 Frame INFO: LCB on port 16 received LMI frame 11:45:29 Frame DEBG: received Report Type IE 11:45:29 Frame DEBG: Link Integrity message 11:45:29 Frame DEBG: received Link Integrity IE

Remote CSU/DSU Problem Response

This is a sample of a remote CSU/DSU not communicating properly: 11:57:39 Frame WARN: LMI on port 16 fault event: status response not received 11:57:39 Frame CRIT: LMI on port 16 in error: data traffic stopped 11:57:39 Frame DEBG: N393 = 0 N392 = 0 11:57:39 Frame INFO: LMI on port 16 waiting for Full Status Response 11:57:49 Frame WARN: LMI on port 16 fault event: status response not received 11:57:49 Frame DEBG: N393 = 1 N392 = 1 11:57:49 Frame INFO: LMI on port 16 waiting for Full Status Response 11:57:59 Frame WARN: LMI on port 16 fault event: status response not received 11:57:59 Frame DEBG: N393 = 2 N392 = 2 11:57:59 Frame INFO: LMI on port 16 waiting for Full Status Response 11:58:09 Frame WARN: LMI on port 16 fault event: status response not received

Host CSU/DSU Problem Response:

This is a sample of a host CSU/DSU not communicating properly: 13:16:59 Frame INFO: LMI on port 16 waiting for Full Status Response **************** 5 messages dropped **************** 13:17:09 Frame INFO: LMI on port 16 waiting for Link Integrity Status Response **************** 5 messages dropped **************** 13:17:19 Frame INFO: LMI on port 16 waiting for Link Integrity Status Response **************** 5 messages dropped **************** 13:17:29 Frame INFO: LMI on port 16 waiting for Link Integrity Status Response **************** 5 messages dropped **************** 13:17:39 Frame INFO: LMI on port 16 waiting for Link Integrity Status Response **************** 5 messages dropped **************** 13:17:40 Frame DEBG: Port 16 received frame 13:17:40 Frame INFO: frame in error: unspecified error 13:17:49 Frame INFO: LMI on port 16 waiting for Link Integrity Status Response **************** 5 messages dropped ****************

CIR Mismatch Response

This speed setting is assigned by your service provider. This is a sample of an incorrect CIR setting: 13:16:59 Frame INFO: LMI on port 16 waiting for Full Status Response **************** 5 messages dropped **************** 13:17:09 Frame INFO: LMI on port 16 waiting for Link Integrity Status Response **************** 5 messages dropped **************** 13:17:19 Frame INFO: LMI on port 16 waiting for Link Integrity Status Response **************** 5 messages dropped **************** 13:17:29 Frame INFO: LMI on port 16 waiting for Link Integrity Status Response **************** 5 messages dropped **************** 13:17:39 Frame INFO: LMI on port 16 waiting for Link Integrity Status Response **************** 5 messages dropped **************** 13:17:40 Frame DEBG: Port 16 received frame 13:17:40 Frame INFO: frame in error: unspecified error 13:17:49 Frame INFO: LMI on port 16 waiting for Link Integrity Status Response **************** 5 messages dropped ****************

Bad Cabling

Specific cabling is required. This is a sample of bad cabling or bent pins on the connector: 15:21:49 Frame CRIT: LMI on port 16 in error: data traffic stopped 15:27:46 Frame DEBG: Port 16 received frame 15:27:46 Frame INFO: LCB on port 16 received LMI frame 15:27:46 Frame INFO: LMI bad message type 15:27:49 Frame INFO: LMI on port 16 waiting for Link Integrity Status Response 15:27:49 Frame DEBG: Port 16 received frame 15:27:49 Frame INFO: LCB on port 16 received LMI frame 15:27:49 Frame DEBG: received Report Type IE 15:27:49 Frame DEBG: Link Integrity message 15:27:49 Frame DEBG: received Link Integrity IE 15:27:56 Frame DEBG: Port 16 received frame 15:27:56 Frame INFO: LCB on port 16 received LMI frame 15:27:56 Frame INFO: LMI bad message type 15:27:59 Frame INFO: LMI on port 16 waiting for Link Integrity Status Response 15:27:59 Frame DEBG: Port 16 received frame 15:27:59 Frame INFO: LCB on port 16 received LMI frame 15:27:59 Frame DEBG: received Report Type IE 15:27:59 Frame DEBG: Link Integrity message 15:27:59 Frame DEBG: received Link Integrity IE 15:28:06 Frame DEBG: Port 16 received frame 15:28:06 Frame INFO: LCB on port 16 received LMI frame
 

solutions | partner programs | corporate info | support and training | where to buy
site map | contact us | press releases |
events | promotions | advertising

Copyright © 1996-2001 Digi International. All rights reserved.