Use these diagrams as a reference when building or purchasing V.35 cables. See Tips for Building and Purchasing Cables for cable length and quality concerns.
|
DB-25 |
V.35 Signal |
Winchester |
DB-25 Male Connector |
|
2 |
TxD (A) |
P |
|
|
14 |
TxD (B) |
S |
|
|
3 |
RxD (A) |
R |
|
|
16 |
RxD (B) |
T |
Winchester Connector |
|
15 |
TxCLKIN (A) |
Y |
|
|
12 |
TxCLKIN (B) |
AA |
|
|
17 |
RxCLK (A) |
V |
|
|
9 |
RxCLK (B) |
X |
|
|
4 |
RTS |
C |
|
|
5 |
CTS |
D |
|
|
20 |
DTR |
H |
|
|
6 |
DSR |
E |
|
|
8 |
DCD |
F |
|
|
24 |
TxCLKOUT (A) |
U |
|
|
11 |
TxCLKOUT (B) |
W |
|
|
7 |
GND |
B |
|
|
1 and shell |
CGND |
A |