The following error messages may occur while the driver is parsing the parameters.
*Usage Error: AIODGXEM
port=XXX mem=XXXXX
[name=bname] [node=0].
This error will appear if you load the driver with no parameters on ISA bus computers.
*Usage Error: First parameter not 'port='.
The driver expects the first parameter to be port=xxx on ISA machines, but this was not the case.
*Error: Invalid Port Address 0x310.
This message indicates that an invalid port address was specified.
*Error: Port Address 0x304 is already supported.
This message indicates that the driver is already supporting an AccelePort Xem host adapter at this port address.
*Usage Error: Second parameter not 'mem='
The driver expects the second parameter to be mem=xxxxx in ISA machines, but this was not the case.
*Error: Invalid Memory Address 0xF0000.
This message indicates that an invalid memory address was specified.
*Error: AllocateResourceTag failed.
This message indicates that the driver could not allocate resources from NetWare. Unload unnecessary NLMs and reload the driver.
*Error: AIORegisterDriverA failed.
This message indicates that NetWare failed to permit registration of the driver.
*Error: AllocateSemiPermMemory returns NULL.
This message indicates that the driver's request to allocate memory failed. Unload unnecessary NLMs and reload the driver.
*Error: ISA/EISA adapters must be loaded before PCI adapters!
Once PCI support is loaded, you cannot load support for an ISA adapter. Unload the driver. Load all ISA adapters, then reload PCI support.
*AIODGXEM Xem PCI support has already been loaded.
You only need to load the driver once to support all PCI Xem host adapters in the system.
*No PCI BIOS entry point found.
The driver cannot locate the PCI BIOS. Fatal error.
*No usable PCI adapters found.
No functioning PCI Xem host adapters were found.
The following error messages may occur while the driver is performing some initial tests on the AccelePort Xem host adapter.
Adapter 4: Port 304 Mem D0000
*Error: This is not an Xem host adapter
This message indicates that an adapter was found, but it is not an Xem host adapter.
Adapter 4: Port 304 Mem D0000 Failed Hardware Registration.
This message indicates that NetWare failed to accept the driver's attempt to register the adapter's hardware resources.
Adapter 4: Port 304 Mem D0000 Port 304 not found.
This message indicates that the driver could not find an adapter with port 304h. Check to insure that you have specified the correct I/O port or that you have properly configured the adapter's port address.
Adapter 4: Port 304 Mem D0000 Hardware Reset Fails.
This message indicates that the driver could not place the adapter into a reset state. This is most likely the result of an I/O port address conflict or a faulty adapter. Be sure that there are no other I/O ports in your system at the indicated I/O port address.
Adapter 4: Port 304 Mem D0000 Memory not found error x.
This message indicates that the driver could not find the adapter's memory. x indicates the number of memory errors found in a 256 byte block.
Adapter 4: Port 304 Mem D0000 Memory error x.
This message indicates that the driver has found the adapter's memory, but it appears to be faulty. x indicates the number of errors found in a 256 byte block.
Adapter 4: Port 304 Mem D0000 Memory fails disable.
This message indicates that the adapter's memory could not be disabled. This could be the result of a memory overlap with some other memory in the system, or a faulty adapter. Ensure that no memory conflict exists.
The following messages may occur during the driver's attempt to initialize the adapter.
Adapter 4: Port 304 Mem D0000 BIOS fails initialization.
This message indicates that the host adapter's on-board BIOS did not initialize properly.
Adapter 4: Port 304 Mem D0000 FEPOS fails initialization.
This message indicates that the on-board operating system did not initialize successfully.
Adapter 4: Port 304 Mem D0000 FEPOS finds 0 ports.
This message indicates that the on-board operating system initialized successfully, but found no ports. Check to see that the PORTS modules are connected to the AccelePort Xem host adapter.
Adapter 4: Port 304 Mem D0000 Command failure during Initialization.
This message indicates that the on-board operating system encountered a failure during initialization of the asynchronous channels.