SCSI Terminal Server Specifications

WARNING: To prevent electric shock, do not remove the cover of a SCSI Terminal Server module. There are no user-serviceable parts inside. Refer servicing to qualified personnel.

AC Power Requirements (maximum)

Models 1002, 1008, 1400, 1800, 1610, 1616

Two external power supplies available:
120 VAC, 60 Hz, 15VA (U.S., Canada)
100-240 VAC, 50-60 Hz, 15VA (universal)

Model 1032

100-240 VAC, 50-60 Hz, 25VA internal power supply

The recommended power cord for North American units is:
UL Listed, CN, detachable type SJT or SVT, 3 conductor, 18 AWG, rated 125 V, 10 A.
 
Environmental

Ambient temperature:
Models 1002, 1008, 1400, 1800, 1610, 1616

50°F (10°C) to 122°F (50°C)

Ambient temperature:
Model 1032

50°F (10°C) to 95°F (35°C)

Relative humidity

5% to 90% non-condensing

Altitude

0 to 12,000 feet (0 to 3650 meters)
 
Serial Interface Surge Suppression
15 kilovolts per IEC 1000-4-2, Level 4
 
Mechanical

Models 1002, 1008

Height: 1.2 inches (3.1 cm)
Width: 8.1 inches (20.6 cm)
Depth: 5.9 inches (14.8 cm)
Weight: 1.2 lbs. (0.6 kg)

Models 1400, 1800

Height: 1.1 inches (2.8 cm)
Width: 8.1 inches (20.6 cm)
Depth: 5.5 inches (14.1 cm)
Weight: 1.0 lbs. (0.5 kg)

Model 1610

Height: 1.2 inches (3.1 cm)
Width: 11.5 inches (29.3 cm)
Depth: 5.4 inches (13.8 cm)
Weight: ?.? lbs. (?.? kg)

Model 1616

Height: 1.2 inches (3.1 cm)
Width: 8.1 inches (20.6 cm)
Depth: 5.5 inches (14.1 cm)
Weight: 2.1 lbs. (1.0 kg)

Model 1032

Height: 1.8 inches (4.5 cm)
Width: 15.1 inches (38.4 cm)
Depth: 7.6 inches (19.2 cm)